Welcome to Winwin ,
We offer PCB,PCB assembly,all kinds of components(LRC and all the parts you need ),


Free shipping PM2.5/PM10 Sensor RS485 modbus Particle detection sensor transmitter 10-30V 0-1000ug/cubic meter 485 Air quality








- 485 communication (modbus) protocol baud rate: 2400.4800 (default) .9600
- Data bit length: 8 bits
- Parity mode: none
- Stop bit length: 1 bit
- Default modbus communication address: 1
- Support function code: 03
Wiring instructions
Cable color |
Description |
|
Power |
Brown |
Power+ (10-30vdc ) |
black |
Power – |
|
Communication |
yellow |
485-A |
Blue |
485-B |
Communication protocol
Basic communication parameters
Code |
8-bit binary |
Data bit |
8 bit |
Parity bit |
NO |
Stop bit |
1 bit |
Error check |
CRC |
Baud rate |
2400bit/s, 4800bit/s, 9600 bit/s default is 4800bit/S |
4.2 Data frame format definition
Adopt Modbus-RTU communication protocol, the format is as follows:
Initial structure ≥ 4 bytes of time
Address code = 1 byte
Noise Transmitter Instruction Manual (Type 485) V2.0
Function code = 1 byte
Data area = N bytes
Error check = 16-bit CRC code
End structure ≥ 4 bytes of time
Address code: is the address of the transmitter, which is unique in the communication network (factory default 0x01).
Function code: The instruction function of the command sent by the host. This transmitter only uses function code 0x03 (read register data).
Data area: The data area is the specific communication data. Note that the 16bits data high byte is in front!
CRC code: Two-byte check code.
Host inquiry frame structure:
Address code |
Function code |
Register start address |
Register length |
check code low |
Check code high |
1 bytes |
1 bytes |
2 bytes |
2 bytes |
1 bytes |
1 bytes |
Slave transponder frame structure
Address code |
Function code |
effective byte |
No 1 Data area |
NO2 Data area |
No N Data area |
Check code |
1 bytes |
1 bytes |
1 bytes |
2 bytes |
2 bytes |
2 bytes |
2 bytes |
Register address
Register address |
PLC or configuration address |
content |
operation |
0000 H |
40001 |
PM2.5 Upload data is the real value |
Read only |
0000 H |
40002 |
PM10 Upload data is the real value |
Read only |
4.4 Communication protocol examples and explanations
Example: Read the PM value of device address 0x01
Inquiry frame:
Address code |
Function code |
Start address |
Data length |
check code low |
Check code high |
0x01 |
0x03 |
0x00 0x00 |
0x00 0x02 |
0xC4 |
0x0B |
Response frame: (eg read 85ug/m3 for PM2.5 and 156ug/m3 for PM10)
Address code |
Function code |
effective byte |
humidity |
temperature |
check code low |
Check code high |
0x01 |
0x03 |
0x04 |
0x00 0x55 |
0x00 0x9c |
0xEA |
0x4A |
PM2.5 calculation:
Air quality (PM2.5/P10) transmitter instruction manual (type 485) V2.0
PM2.5:0055 H (hexadecimal) = 85=> PM2.5 = 85ug/m3
PM10 calculation:
PM10:009CH (hexadecimal) = 156 => PM10 = 156ug/m3
We wil provide more information and intall information after you buy it ,
​thank you
More options for Transmitter.
CO gas sensor module with humidiity temperature Transmitter 4-20MA/0-10V /0-5V/RS485
0-65535lux 3in1 light intensity sensor/RS485 modbus protocol Temperature and humidity Transmitter
Light intensity sensor Transmitter 4-20mA 0-10V 0-5V
0-65535lux Light intensity sensor Transmitter RS485
0-200000lux 3in1 light intensity sensor/RS485 modbus protocol Temperature and humidity Transmitter
0-200000lux Light intensity sensor Transmitter RS485
TVOC Transmitter MODBUS RS485 Air Quality Transmitter 0-60000ppb
High precision RS485 CO2 Transmitter
co2 gas sensor module 485 modbus
CO2 sensor module 4-20mA /0-10V /0-5V CO2 Transmitter
noise sensor transmitter Rs485 modbus
noise sensor transmitter 4-20mA/0-5V/0-10V
Flooding transmitter RS485 Modbus +Switch output
Flooding transmitter sensor Leak detection alarm sensor Relay output
Temperature and humidity sensor Transmitter RS485 with probe
waterproof Temperature and humidity sensor Transmitter RS485
waterproof Temperature and humidity sensor Transmitter RS485 Transmitter
soil PH sensor module RS485 MODBUS-RTU
soil PH sensor module RS485 MODBUS-RTU WITH LED display
PM2.5 PM10 Dust detector Transmitter 4-20mA/0-10V Air quality transmitter
PM2.5/PM10 Sensor RS485 modbus transmitter
NH3 sensor module 4-20mA /0-10V NH3 Transmitter
NH3 sensor module RS485 MODBUS-RTU NH3 Transmitter
atmospheric pressure sensor Transmitter RS485
Atmospheric pressure sensor Transmitter 4-20mA/0-5V/0-10V
LEL Transmitter sensor 0-5V/0-10V/4-20MA
LEL Transmitter sensor CH4 C3H8 Combustible gas detector sensor RS485
Rain and snow Transmitter Switch type
Rain and snow Transmitter RS485 + Switch type
Rain and snow Transmitter RS485+Switch type with heating
Rain and snow Transmitter Switch type with heating
aluminum wind speed sensor Transmitter 0-20MA/0-10V /0-5V/RS485
aluminum wind speed sensor Transmitter pulse PNP NPN NPNR output
Metal 360 degree Wind direction sensor transmitter 4-20ma/0-10v/0-5V
Metal 360 degree Wind direction sensor transmitter RS485 ModBus-RTU
Customer Service
PAYMENT
1.Aliexpress supports Visa , Boleto , MasterCard ,Maestro Debit Card ,Western Union,Webmoney,QIWI and wire transfer via bank.
2.If you still have any question for payment, please feel free to contact us freely .
SHIPPING
1.When you place an order, please choose a shipping method and pay for the order including the shipping fee.
2.We will send the items with 2-5days once the payment is confirmed by the system.
3. Any import Taxes is not included in the shipping fee, buyers are responsible for the customs duties when it is occurred .
4.Any request to get the refund ,please send back the items back to us. Customers should pay the freight back to China if problems if yours .
on the other side, if problem is ours we will pay the shipping fee.
5.Express shipping (DHL,Fedex,UPS,TNT etc) and post service are provided for the shipping. 3-7Days will be arrived to your door by Express shipping
Post service Such as China Post Register Air Mail ,Singapore post, Hongkong Post Air Mail reach most countries within 15-45 business days,
Some destination and other factors may take up to 60 business days.
Please pay attention : Order less than 7 USD will not have tracking number but you will get the items for sure,
please contact us to get a refund or resent if you don’t get within 60 working days .
FEEDBACK
1.Your satisfaction and positive feedback is very important to us, please leave positive feedback and 5 stars if you are satisfied with our items and service .
2.If you have any problems with our items or our items or service , please feel free to contact us first before you leave negative feedback .
We will do our best to solve any problems and provide you with the best customer service .
CONTACT US
1. Service to worldwide,Wholesale ,retail, drop shipping , Customized support.
2. Working time: (UTC+8) 8:45-12:00am; 13:00-22:00 pm .Feel free to contact us
If you need USB to RS485 Module , please buy here




Reviews
There are no reviews yet.